82.5 kVA TO 200 kVA GENSETS

Gensets powered by best-in-class Engine, Alternator & Controller

Mahindra mPOWER Engine

  • Higher block loading capacity
  • Linear fuel consumption
  • Low ownership cost
  • Mechanical/Common rail fuel injection system
  • Modular cylinder head for easy serviceability

Genset Controller

Premium controller that delivers accurate metering, best-in-class protection for optimum genset performance. With Genset controller, the genset is always protected against breakdowns from electrical or mechanical flaws and thereby ensures maximum uptime.

Key features

  • Compatible with Auto Mains Failure facility
  • 500 event log memory storage
  • Comes with RS 485 port for modbus communication as standard scope
  • Activation time delay for oil pressure,coolant temperature, voltage and frequency faults
  • Routine maintenance & service alerts
  • 5 configurable inputs
  • Sleep mode
  • Remote start & stop facility

Genset Monitoring (Key Parameters)

  • Generator/load power (kW,kVA,kVAr,pf),generator/load current,battery voltage
  • RPM,running hours,oil pressure,engine temperature and fuel level

Genset Protection (Key Parameters)

  • High engine temperature,low oil pressure,engine over/under speed
  • Over current,over/under voltage,Charging alternator low voltage

Alternator

  • Brushlee type, screen protected,revolving field,self-excited alternator conforming to IS/IEC 60034-1
  • 3 Phase reconnect type winding with 12 terminals brought out for connection
  • Superior winding for harmonic reduction
  • Epoxy coating for consistent performance in all weather conditions
  • Better transient response capability

Acoustic Enclosure

  • Aesthetically designed at Mahindra Research Valley
  • Designed by using latest technology aids like Computer aided Engineering (CAE),Noise-Vibration Harshness Engineering (NVH) and Computational Fluid Dynamics Engineering (CFD) which resulted in lowest foot print & lowest noise levels

Optional Accessories

PMG alternator,RTD/BTD Space Heater,Coolant / Oil heater , Heavy duty air cleaner , synchronization . For more details kindly contact our authorised representative

Genset Specifications:

Genset Prime Rating (kVA) 82.5 100 125 160 180 200
Genset Prime Rating (KW) 66 80 100 128 144 160
Phase/Voltage (V) 3/415
Power Factor (lagging) 0.8
Current (A) 115 139 174 223 251 278
Frequency (Hz) & RPM 50/1500
Governing class G2 as par ISO 8528 Part V
Starting system 12 V DC Elec 12 V DC Elec 24 V DC Elec 24 V DC Elec 24 V DC Elec 24 V DC Elec
Fuel tank capacity (lit) 200 200 219 300 400 400
Canopy dimensions w/o Silencer (L ✕ W ✕ H*)(mm) approx 3200 ✕ 1200 ✕ 1600 3200 ✕ 1200 ✕ 1600 3750 ✕ 1030 ✕ 1550 3790 ✕ 1300 ✕ 1800 4500 ✕ 1400 ✕ 1800 4500 ✕ 1400 ✕ 1800
Genset weight (kg) (approx.) 1700 1750 1900 2350 2750 2800

Engine Specifications

Make/Series Mahindra mPOWER
Model mPower41015G mPower41265G mPower61565G mPower61995G mPower62235G mPower62485G
Rated Power at 100% Load (HP) 101 126 156 199 223 248
Aspiration TCA TCA TCA TCA TCA TCA
No. of cylinders 4 4 6 6 6 6
Bore ✕ Stroke (mm) 105 ✕ 137 105 ✕ 137 105 ✕ 137 105 ✕ 137 105 ✕ 137 105 ✕ 137
Displacement (lit) 4.8 4.8 7.2 7.2 7.2 7.2
Fuel consumption @ 75% load (lit/hr)^ 13.9 17.3 21.4 27.8 28.7 33.3
Fuel consumption @ 100% load (lit/hr)^ 18.1 23.1 28 36.7 38.2 40.8
Lube oil specification 15W40 API CI4+ 15W40 API CI4+ 15W40 API CI4+ 15W40 API CI4+ 15W40 API CI4+ 15W40 API CI4+
Total lube oil system capacity (liter) 13.5 13.5 20.2 20.2 20.2 20.2
Lube oil consumption @ full load$ 0.1% of Fuel Consumption
Lube oil change period (hrs.) 500
Radiator coolant capacity (liters) 19 19 22.5 25 24 24

Alternator Specifications

Make Mahindra Powerol
Enclosure Type IP23
Voltage regulation ± 1%
Class of insulation Class H
Maximum Unbalanced Load across Phases 25%
Note :

Above specifications are subject to change without prior notice due to continuous product improvements

All engines & alternators conform to respective IS standards

All the genset specifications conform to ISO8528 standard

Fuel – High Speed Diesel (HSD IS 1460:2005)

^Considering 0.845 specific gravity of diesel, 5% tolerance

$ Considering 0.89 specific gravity of oil

* For Standby duty,contact Powerol authorized representative

All specifications at standard NTP operating conditions